|
|
Brian Sims
Editor |
| Home> | Fire | >Passive Fire Protection | >New industry Technical Committee issues first fire safety guidance |
New industry Technical Committee issues first fire safety guidance
01 March 2026
THE MASONRY Association of Great Britain (MAGB) has formally announced the creation of its new Technical Committee, itself a cross-sector body established to strengthen technical leadership and raise standards across masonry construction, alongside the publication of its first official Technical Note focused on fire safety.

Technical Note TN-01/26 addresses the installation of cavity fire barriers and raises concerns about the increasing use of zero-compression products, which the Technical Committee believes present “a foreseeable long-term life safety risk” when used in structures subject to movement. The publication represents the first step in a broader programme of work aimed at raising awareness of long-term fire safety performance within masonry construction.
The Masonry Association’s Technical Committee brings together senior technical specialists from across the masonry supply chain, including brick and component manufacturers, fire barrier and insulation suppliers, façade contractors, structural engineers, warranty providers and training bodies. The Committee has been established to identify emerging technical risks within masonry construction, provide clear evidence-based guidance and help bridge the gap between laboratory testing and real-world building performance.
TN-01/26 represents the Committee’s first formal publication and signals a more proactive technical role for the Association.
The Association has confirmed that further Technical Notes and guidance documents will follow, forming part of an ongoing commitment to improve understanding of real-world building performance and lifecycle safety.
Not static systems
The Technical Note explains that, while zero-compression cavity barriers may achieve compliance in laboratory fire testing, buildings are not static systems. Structural frame shortening caused by creep and shrinkage, brickwork settlement, mortar movement, thermal expansion and construction tolerances can all increase cavity dimensions over time.
Barriers installed without positive compression rely entirely on perfect geometry at the point of installation. As movement occurs, even gaps of only a few millimetres may allow flame and hot gases to bypass the barrier. Given that these interfaces are concealed once construction is complete, such failures are not detectable through routine inspection, in turn potentially introducing significant life safety, liability and reputational risk.
The Technical Committee’s guidance states that fire safety performance must be considered over the full life of a building rather than solely at the point of laboratory tests. It recommends that horizontal and vertical cavity fire barriers are installed with compression (with a nominal minimum preload of 5 mm unless greater compression is justified by manufacturer testing) in order to maintain contact and integrity under long-term movement conditions.
Senior technical representatives
The Technical Committee is chaired by Keith Aldis of MAGB and brings together senior technical representatives from across the full masonry supply chain. Its membership spans brick and component manufacturing, stone and GRC, mortar and structural systems, cavity barriers and insulation, damp-proofing and membranes, fixings, installation specialists, engineering, warranty providers and education and training bodies. This breadth of expertise ensures that guidance is technically rigorous and grounded in practical site experience.
Keith Aldis commented: “This Technical Committee has been formed to bring senior technical expertise from across the masonry sector into one forum with a clear purpose: to identify emerging risks and provide practical and evidence-based guidance to the industry.”
Aldis continued: “Our first Technical Note (ie TN-01/26) reflects our collective assessment of how buildings behave in reality over time. Laboratory fire testing is conducted under controlled conditions, but real structures are subject to settlement, shrinkage and differential movement. Positive compression in cavity fire barriers is fundamental to maintaining contact and continuity as that movement occurs. Our guidance is intended to support long-term fire integrity and promote durable and movement-tolerant solutions across the sector.”
In conclusion, Aldis noted: “This publication is the first in a series of Technical Notes intended to support long-term fire integrity and promote movement-tolerant and durable solutions across the sector.”
*Copies of TN-01/26 are available online at www.masonryassociation.co.uk
- Residents feel safer in their homes following fire service checks
- UCLan study exposes failings of UK’s furniture fire safety regulations
- “Salvage plans must be in place for historic venues” warns London Fire Brigade
- Fire Safety Matters launches new industry podcast
- Fire Safety Matters to run interactive Women in Fire Safety webinar
- New chief for SRFS
- Bradford brings in BBQ ban on moorland
- Fire Standards Board England website goes live
- Zaun partners with Rimal Global Group in Oman
- Everbridge Interview with Tom Pressley
- Worry over passive fire protection in Scottish schools
- From the editor
- Fire safety returns home to NEC Birmingham
- Blog for FSM website
- Fire Safety Event 2017 - Live Coverage
- Passive fire protection critical for life safety
- From the editor
- Tall order
- School of thought
- Fire safety on the agenda in Scotland









