Brian Sims
Editor |
Home> | Fire | >Passive Fire Protection | >ASFP issues trio of Advisory Notes focused on passive fire protection guidance |
ASFP issues trio of Advisory Notes focused on passive fire protection guidance
05 June 2023
THE ASSOCIATION for Specialist Fire Protection (ASFP) has published three new Advisory Notes centred on passive fire protection and updated another. The documents cover a range of topics related to firestopping, penetration seals and smoke seals.
Advisory Note 13 outlines the testing of partial penetrations, for example, socket boxes, which are installed into dry wall systems. Firestopping products are made to help maintain the performance of a wall where such electrical boxes have been added. A CEN standard is currently being drafted to cover the testing of these products.
In the interim, Advisory Note 13 suggests that the firestopping of these products is undertaken using an ad hoc approach based on testing to BS EN 1364-1: Fire Resistance Tests for Non-Load Bearing Elements – Walls.
Advisory Note 30 covers the transition from CE marking to the UKCA mark. It explains how all of the different passive fire protection product families are affected, duly describing the likely next steps in the process. In essence, Advisory Note 30 aims to help manufacturers and specifiers alike to understand what will be required during the transition period.
Smoke seals and fire curtains
Advisory Note 31 covers smoke seals used in conjunction with active fire curtains. It was produced in response to false claims that manufacturers used draught excluders to prevent the passage of cold smoke and that these would be of limited use in a fire resistance test scenario.
The document explains that the performance smoke seals used are the same technology as that which might be employed in smoke leakage-rated fire-resisting doors. Where smoke seals are added for a leakage test, they also have to be present for the corresponding fire test.
Advisory Note 15 has been updated. This looks at the interchange of flexible wall systems for service penetration seal systems. When first published, the Advisory Note provided pictorial clarification of a long-winded statement in BS EN 1366-3: 2009: Fire Resistance Tests for Service Installations – Penetration Seals. This standard has been amended and some of the scenarios permitted in the 2009 version are not now reproduced in the 2021 version.
The drawings in AN15 have been amended to bring them into line with BS EN 1366-3: 2021.
*ASFP Advisory Notes are available to download for free from the online ASFP Publications Library. Visit https://asfp.org.uk/page/Publicationslist
- New dates for Foundation Course in Passive Fire Protection issued by ASFP
- Jo O’Neill and Adam Shipstone appointed in key roles at ASFP
- ASFP set to host fire safety seminar in Scotland
- ASFP welcomes “comprehensive, concise and hard-hitting” findings of Grenfell Tower Inquiry
- ASFP expands top team
- ASFP issues new Advisory Notes on fire protection of structural steel
- Finalists for 2024 Passive Fire Protection Awards unveiled by ASFP
- ASFP shortlisted for trio of Memcom Excellence Awards
- New Association Council appointed by ASFP at 2024 AGM
- ASFP announces duo of “significant” appointments
- Worry over passive fire protection in Scottish schools
- From the editor
- Fire safety returns home to NEC Birmingham
- Blog for FSM website
- Fire Safety Event 2017 - Live Coverage
- Passive fire protection critical for life safety
- From the editor
- Tall order
- School of thought
- Fire safety on the agenda in Scotland